Non-Potable Water Self-Adhesive Pipe Marker
Item #
N41 Y/B
EZ Marker Reads
Non-Potable Water
Compliance
  • ANSI / ASME
  • ECCN Certification

Non-Potable Water Self-Adhesive Pipe Marker

Size:

Material:

Laminate:

Mounting:

Packaging:

Price:
$1.56
Qty
Each
  • 1–99
    $1.56
  • 100–249
    $1.40
  • 250+
    $1.26

Your item has been added to cart.

0 In Stock
Special freight arrangements are necessary.

Need a quote for a large order? Call 855‑444‑9477 or email us.

Product Information

Details

This Non-Potable Water Self-Adhesive Pipe Marker uses informational messages for safety identification and compliance. A Non-Potable Water Self-Adhesive Pipe Marker is a useful tool to help protect the health and safety of personnel, but is not a substitute for required protective measures for eliminating or reducing hazards.

Compliance

Self-Adhesive Pipe Markers

Our self-adhesive markers make labeling pipe contents a breeze. All you need to do is simply peel the label off the protective backing and stick into place. These markers are made with our specially-formulated InfiniStick™ adhesive for maximum durability and long-lasting adhesion when applied to a clean and dry surface.

Durability
4 to 5 years
Service Temp
-20 °F to 200 °F (-29 °C to 93 °C)
Minimum Application Temp
50 °F
Surface Prep
Clean and dry
Spec Compliance
ANSI / ASME A13.1 2020 (if used in conjunction with arrows, sold separately)
  • Self-Adhesive Pipe Marker with Arrow Banding Tape
  • Self-Adhesive Pipe Marker with Arrow Banding Tape
  • Self-Adhesive Pipe Marker with Arrow Banding Tape

Size Chart (Pipe Overall Diameter, Marker Size, & Letter height)

The following chart shows the recommended pipe marker letter height and marker size based on the outside pipe diameter, including the insulation of the pipe to be identified. For pipes with an O.D smaller than 3/4″ (19mm) and for valve and fitting identification, the use of a permanent legible tag is recommended.

  • Self-Adhesive Pipe Marker with Arrow Banding Tape
    STYLE 1XSM

    Additional information below.

    Pipes with Diameter (O.D)
    0.7″ to 1.3″ (18 to 33 mm)
    Marker Length: 8″ (200 mm)
    Legend Height: 0.5″ (13 mm)

  • Self-Adhesive Pipe Marker with Arrow Banding Tape
    STYLE 1SM

    Additional information below.

    Pipes with Diameter (O.D)
    1.4″ to 2.4″ (34 to 61 mm)
    Marker Length: 8″ (200 mm)
    Legend Height: 0.7″ (19 mm)


  • Self-Adhesive Pipe Marker with Arrow Banding Tape
    STYLE 1

    Additional information below.

    Pipes with Diameter (O.D)
    2.5″ to 7-7/8″ (62 to 170 mm)
    Marker Length: 12″ (300 mm)
    Legend Height: 1.3″ (32 mm)

  • Self-Adhesive Pipe Marker with Arrow Banding Tape
    STYLE 1LG

    Additional information below.

    Pipes with Diameter (O.D)
    6.8″ to 10″ (171 to 254 mm)
    Marker Length: 24″ (600 mm)
    Legend Height: 2.5″ (64 mm)

  • Self-Adhesive Pipe Marker with Arrow Banding Tape
    STYLE 1XLG

    Additional information below.

    Pipes with Diameter (O.D)
    Over 10″ (Over 254 mm)
    Marker Length: 32″ (800 mm)
    Legend Height: 3.5″ (89 mm)

ANSI / ASME Size Table

Pipe O.D. Text Size Marker Style Maximum Characters
3/4" - 1 1/4" 0.5" 1XSM 22
1 1/2" - 2" 0.75" 1SM 18
2 1/4" - 6" 1.3" 1 22
8" - 10" 2.5" 1LG 22
Over 10" 3.5" 1XLG 22

Latest Revision ANSI / ASME A13.1

ANSI / ASME is the most common pipe identification standard used in the United States. The standard specifies the primary and secondary means of identifying pipe content, as well as the size, color and placement of the identification device.

1. Primary Identification

The legend (name of pipe content) and directional flow arrow remain the primary means of identifying pipe content. The size and placement of the marker and arrow has not changed. See ANSI / ASME size table and installation recommendations for details.

Legends should use arrows to indicate the direction of flow, where flow can be in both directions, arrows in both directions should be displayed. Contents should be identified by a legend with sufficient additional details such as temperature, pressure, etc. Legends should be brief, informative, pointed, and simple for greatest effectiveness.

  • Marker illustration

1.1 Additional Means of Identification ASME A13.1

ASME A13.1 incorporated the GHS pictograms into the 2015 revision and has recommended their use as part of the legend.

"The applicable GHS pictograms as illustrated in Fig.1 may be included as part of the legend. Where piping is connected to containers that are labeled in accordance with GHS requirements, a corresponding label on the piping may be provided. The corresponding label should contain at least the product name or identifier, the pictogram, the signal word, and the physical, health, and environmental hazard statements."

  • GHS Pictogram
Fig.1

2. Secondary Identification

ASME A13.1 4.2 Color: "Color should be used to identify the characteristic hazards of the contents. Color should be displayed on, or contiguous to, the piping by any physical means, but its use shall be used in combination with a legend. Color may be used in continuous, total-length coverage or in intermittent displays. Colors preceded by the word "Safety" shall meet the requirements of ANSI / NEMA Z535.1"

  • FLUID SERVICE COLOR COMBINATIONS
    Fire Quenching Fluids

    Safety Red Background / White Legend

    Toxic & Corrosive Fluids

    Safety Orange Background/ Black Legend

    Flammable Fluids

    Safety YellowBackground / Black Legend

    Combustible Fluids

    Safety Brown Background /White Legend

    Potable, Cooling, Boiler feed, & other Water

    Safety Green Background/ White Legend

    Compressed Air

    Safety Blue Background / White Legend

    Defined by the User

    Safety Purple Background / White Legend

    Defined by the User

    Safety White Background / Black Legend

    Defined by the User

    Safety Gray Background / White Legend

    Defined by the User

    Safety Black Background / White Legend

Flammable Fluids
Used for fluids that, under ambient or expected operating conditions, are a vapor or procedure vapors that can be ignited and continue to burn in air. The terms thus may apply, depending on service conditions, to fluids defined for other purposes as flammable or combustible
Oxidizing Fluids
Oxidizing fluid is any gas or liquid that may, generally by providing oxygen, cause or contribute to the combustion of other material more than air does.
Fire Quenching Fluids
This classification includes water, foam and CO2 used in sprinkler systems and fire fighting piping systems.
Toxic & Corrosive Fluids
This classification includes fluids that are corrosive or toxic, or will produce corrosive or toxic substances when released.
Combustible Fluids
This classification includes fluids that can burn but are not flammable.

3. Placement

  • Marker visibility

Always position pipe labels on pipes to achieve the best visibility. Install pipe labels below or above the horizontal centerline of the pipe when pipes are located above or below the normal line of vision.

  • Pipe marker illustration
    Install pipe labels close to valves or flanges.
  • Plastic Lockout Hasp 428 C3504
    Apply pipe labels adjacent to changes in direction and/or branches.
  • Marker installation options
Install pipe labels before and after all wall, floor and ceiling penetrations.
  • Marker installation options
Install pipe labels at frequent intervals on straight pipe runs Brimar recommends 20 to 25ft.

4. Abandoned Piping

Piping that has been abandoned in place should be identified. The recommended color scheme is a safety white background with black letters. A black border should be added to the identification. When the abandoned piping is protected from corrosion by the addition of a pressurized fluid or contains residual hazardous material, the legend should indicate that.

Reviews

855‑444‑9477
Cart

Your cart is empty.